Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home2/glowppdk/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the samdevone-core domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home2/glowppdk/public_html/wp-includes/functions.php on line 6114
Junction Boxes Dc & Ac DB – Glow Power Technology

Junction Boxes Dc & Ac DB

Salient features of Junction Boxes Dc & Ac DB.

  • User friendly LED + LCD indication
  • Units saved (kWh)by using solar will be displayed in LCD
  • State of art MOSFET Based, PWM ,MPPT Controlled DSP Technology
  • Efficiency ≥85%
  • Hybrid Charging
  • Sine Wave output that runs your expensive appliances efficiently
  • User selectable Solar and Grid mode, UPS and Normal Modes
  • Ideal for computers
  • It will automatically sense battery condition and increase battery life and minimize water topping

Product List

AJB Models

DCDB Models

ACDB Models

AJB Models

S.no Description SPD
1 3 in 1 out with out DC MCB Yes
2 3 in 1 out with 500V 32 A DC MCB Yes
3 4 in 1 out with out DC MCB Yes
4 4 in 1 out with 500V 32 A DC MCB Yes
5 5 in 1 out with out DC MCB Yes
6 5 in 1 out with 550V 63 A DC MCB Yes
7 6 in 1 out with out DC MCB Yes
8 6 in 1 out with 63 A DC MCB Yes
9 8 in 1 out with 100 A DC Isolator Yes
10 10 in 1 out with 160 A DC Isolator Yes
11 12 in 1 out with 160 A DC Isolator Yes
12 16 in 1 out with 200 A DC Isolator Yes
13 24 in 1 out with 315 A DC Isolator Yes

Full Technical Specification of AJB Models is available here. View or Download

DCDB Models

1 1-1 Out with 1000V DC SPD & 500V DC MCB (1-4Kw) Yes
2 1-1 Out with 600V DC SPD & 500V DC MCB (1-4Kw) ( R ) Yes
3 1-1 Out with 1-SPD & 800V DC MCB  (For 5KW) 1-MPPT Inverter Yes
4 2-2 Out with 2 Nos 1000V DC SPD & 500V DC MCB (4-7.5Kw) Yes
5 2-2 Out with 2 Nos 600V DC SPD & 500V DC MCB (4-7.5Kw) (R ) Yes
6 2-2 Out with 2 – SPD & 800 V DC MCB (For 2-MPPT Inverter) (8-11.5 Kw) Yes
7 3-3 Out with 2 – SPD & 800 V DC MCB ( For 2 – MPPT Inverter) (12 – 15Kw) Yes
8 4-4 Out with 2 – SPD & 800 V DC MCB ( For 2 – MPPT Inverter) (15 – 20Kw) Yes
9 5-5 Out with 2 – SPD & 800 V DC MCB ( 20 – 25 KW) Yes
10 6-6 Out with 2 – SPD & 800 V DC MCB ( 25 – 30KW) Yes
11 8-8 Out with 2 – SPD (Delta Inverter & with out DC MCB (2 – MPPT Inverter) (30-40Kw) Yes
12 10-10 Out with 3-SPD & with out DC MCB (3 – MPPT Inverter) 40-60KW Yes
13 12-12 Out with 3-SPD & with out DC MCB (3 – MPPT Inverter) 40-60KW Yes

ACDB Models

1 1-5 KW Single Phase with Phoenix SPD  Yes 
2 1-5 KW Single Phase without SPD  No 
3 5-10 KW Three Phase with RYB indicator  Yes 
4 5-15 KW Three Phase without RYB indicator without No Volt Relay  No 
5 16-25 KW Three Phase without No Volt Relay  Yes 
6 26-40 KW Three Phase without No Volt Relay  Yes 
7 10-15 KW Three Phase ACDB with No Volt Relay & SPD  Yes 
8 16-20 KW Three Phase ACDB with No Volt Relay & SPD  Yes 
9 21-28 KW Three Phase ACDB with No Volt Relay & SPD  Yes 
10 30-40 KW Three Phase ACDB with No Volt Relay & SPD  Yes 
11 45-60 KW Three Phase ACDB with No Volt Relay & SPD  Yes 
12 80-120 KW Three Phase ACDB with SPP (NVR) -1 in 1 out  Yes 
13 80-120 KW Three Phase ACDB with SPP (NVR) – 2 in 1 out  Yes 
14 80-120 KW Three Phase ACDB with SPP (NVR) – 2 in 1 out with MFM  Yes 

Related Products